 SURFACE MOUNT SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
FEATURES
* * * * * Ideal for surface mounted applications Low leakage current Metallurgically bonded construction Mounting position: Any Weight: 0.016 gram
SA1 THRU SA7
SOD-123F
MECHANICAL DATA
* Epoxy : Device has UL flammability classification 94V-0
.035 (0.90) .028 (0.70) .114 (2.9) .106 (2.7) .077 (1.95) .069 (1.75)
.008 (0.20)
.053 (1.35) .047 (1.20)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
.030 (0.75) .022 (0.55) .150 (3.8) .142 (3.6)
Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TA = 55 o C Peak Forward Surge Current IFM(surge): 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 3) Typical Junction Capacitance (Note 1) Operating and Storage Temperature Range ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS Maximum Forward Voltage at 1.0A DC Maximum DC Average Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C SYMBOL VF IR SA1 SA2 SA3 SA4 1.1 2.0 50 SA5 SA6 SA7 UNITS Volts mAmps mAmps 2006-12 SYMBOL VRRM VRMS VDC IO I FSM RqJA RqJL CJ T J, T STG 25 8 -55 to + 150 SA1 50 35 50 SA2 100 70 100 SA3 200 140 200 SA4 400 280 400 1.0 25 85 30 SA5 600 420 600 SA6 800 560 800 SA7 1000 700 1000 UNITS Volts Volts Volts Amps Amps
0
C/W pF
0
C
NOTES : 1. Measured at 1.0 MHz and applied average voltage of 4.0VDC 2. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 3. Thernal Resistance: Mounted on PCB.
RATING AND CHARACTERISTICS CURVES ( SA1 THRU SA7 )
PEAK FORWARD SURGE CURRENT, (A)
1.0 AVERAGE FORWARD CURRENT, (A) 0.8 0.6 0.4 0.2 0
Single Phase Half Wave 60Hz Resistive or Inductive Load
50 40 30 20 10 0
8.3ms Single Half Sine-Wave (JEDED Method)
0
25
50
75
100
125
O
150
175
0
2
4
6
8 10
20
40
60 80 100
AMBIENT TEMPERATURE, ( C)
NUMBER OF CYCLES AT 60Hz
INSTANTANEOUS REVERSE CURRENT, (mA)
INSTANTANEOUS FORWARD CURRENT, (A)
10
FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE
100 40 10 4 1.0 0.4 0.1
FIG.2 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
TA = 100 OC
1.0
0.1
TA = 100 OC
TA = 25 OC
Pulse Width = 300ms 1% Duty Cycle
0.01
0
0.5
1.0
1.5
2.0
2.5
3.0
0
20
40
60
80
100
120
140
INSTANTANEOUS FORWARD VOLTAGE, (V)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
200
JUNCTION CAPACITANCE, (pF)
FIG.4 TYPICAL REVERSE CHARACTERISTICS
TA = 25 OC
100 60 40 20 10 6 4 2 1 0.1 0.2 0.4 1.0 2 4 10
20
40
100
REVERSE VOLTAGE, (V)
FIG.5 TYPICAL JUNCTION CAPACITANCE
Mounting Pad Layout
0.030 MIN. (0.75 MIN.)
0.035MIN. (0.90 MIN.)
0.165
(4.19) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.


▲Up To Search▲   

 
Price & Availability of SA5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X